You are using an outdated browser. For a faster, safer browsing experience, upgrade for free today.
Premium Multi-Color ESD Tiles for R&D Centers & Tech Labs

Premium R&D Center Aesthetics ESD Tiles

Transform technical workspaces into organized and professional innovation environments with our Premium R&D Center Aesthetics ESD Tiles. Designed for R&D centers, electronics laboratories, technical rooms, production facilities, and other electrostatic-sensitive areas, these conductive PVC tiles combine stable electrical performance with a modular 600 x 600 mm format.

The modular tile design allows contractors and project designers to create color-zoned layouts for work areas, ESD-controlled zones, equipment areas, and safety walkways. With a Class 34+43 use classification, EC conductive performance, controlled dimensional stability, and strong chemical resistance, the flooring is suitable for demanding commercial and industrial environments.

Product Technical Data

Property Test Standard Product Data
Use Classification EN 685 / EN 649 Class 34 + 43
NFPA Life Safety Classification NFPA 101 Class I interior floor finish
Resilient Vinyl Floor Tile Specification ASTM F1700 Pass
European Product Requirements EN 649 / SS-T-312B Pass
Product Safety Performance Underwriters Laboratories Approved for static-conductive flooring used in hazardous locations
Total Thickness EN 428 / ASTM F386 2.0 mm
Tile Size EN 427 / ASTM F536 600 x 600 mm
Product Weight EN 430 Approximately 3.06 kg/m² at 2.0 mm thickness
Dimensional Stability SJ/T 11236-2001
EN 434 / DIN 51962
KS M 3802, by heating
≤0.20%
0.10%
<0.30%
Flexibility ASTM F137 No cracking
Squareness ASTM F540 600 x 600 mm: ±0.30 mm
Residual Indentation SJ/T 11236-2001
EN 433 / DIN 51955
ASTM F142
≤0.30 mm
2.0 mm product: 0.03 mm
3.0 mm product: 0.04 mm
<8.0%
Abrasion and Wear Resistance SJ/T 11236-2001
ASTM D1044, CS-10-F wheel, 500 g
ASTM D4060, CS-10-F wheel, 1000 g, 1000 cycles
Wear loss: ≤0.020 g/cm²
2,500 cycles: 0.48% weight loss
5,000 cycles: 0.95% weight loss
7,500 cycles: 1.41% weight loss
10,000 cycles: 1.87% weight loss
Hardness ASTM D2240 <85
Caster Chair Resistance EN 425 No damage
Static Load Limit ASTM F970 1500 lb/in²
Electrical Resistance SJ/T 11236-2001 / GB 3007-97
DIN 51953 / EN 1081
IEC 61340 / EOS/ESD S7.1
ASTM F150 / NFPA 99 / UL 779
EC conductive grade
2.5 x 104 Ω to <1 x 106 Ω
Static Propensity AATCC 134
SJ/T 10694-1996
<50 V / <100 V
<100 V
Static Decay Time 101C, Method 4046, 5000 V to 0 V
MIL-B-81705C, 5 kV decay time
GB 82605-1996
<0.01 second
<0.02 second
5000 V ±500 V: <2 seconds
Chemical Resistance EN 423 / DIN 51958 / ASTM F925 Excellent; detailed test results available
Ignition and Fire Resistance DIN 4102 / B 3810 / B 3800
SJ/T 11236-2001
GB 8624-1997
Non-burning and not easily ignited
FV-0, <10 seconds
GB 8624 B1
Smoke Density ASTM E662 / NFPA 258 Class 1, <450
Critical Radiant Flux ASTM E648 / NFPA 258 / DIN 51960 Class 1, >1.08 W/m²
Flame Spread Index ASTM E84 / NFPA 225 <75
Outgassing Performance ASTM E595 Excellent; detailed test results available
Color Fastness ISO 105 B02 / Method 3 / DIN 53389 Grade 5–6
Ease of Decontamination DIN 25415-1 / ISO 8690 Excellent
Water Absorption ASTM D570 <0.15%
Slip Resistance EN 13893 / ASTM D2047 0.60 < μ < 0.80; measured value μ = 0.62
Repairable Yes
Recyclable Yes

Trade & Supply Information

  • MOQ: 300 SQM per custom color
  • Lead Time: Approximately 22 days after order confirmation
  • Supply Ability: Up to 150,000 SQM per month
  • Customization: Multi-color combinations can be arranged within one project order, subject to order quantity and production confirmation.

B2B Core Advantages for Architectural Design & Engineering

  • EC Conductive Performance: The conductive resistance range is designed for electrostatic-sensitive workspaces where controlled static discharge is required.
  • Class 34+43 Heavy-Duty Classification: Suitable for intensive commercial use and demanding light-industrial or industrial working environments.
  • Visual Zone Mapping: Modular 600 x 600 mm tiles allow contrasting colors to identify ESD-controlled areas, equipment zones, workstations, and safety walkways.
  • Controlled Dimensional Accuracy: Squareness tolerance of ±0.30 mm supports clean joint alignment and professional large-area installation.
  • Chemical and Decontamination Performance: Excellent chemical resistance and decontamination results support use in laboratories, R&D areas, and technical production environments.
  • Low Static Generation: Static propensity and rapid static decay performance help reduce electrostatic risks around sensitive electronic equipment.
  • Repairable Modular System: Individual damaged tiles can be replaced without removing the entire floor.

Recommended Applications

R&D centers, electronics laboratories, PCB production areas, precision assembly rooms, technical offices, testing centers, equipment rooms, industrial control rooms, ESD-protected areas, and other electrostatic-sensitive commercial or industrial facilities.

Contact Us