Win over facilities managers and large-scale project owners with our No-Wax Maintenance-Free ESD Vinyl Tiles. Traditional anti-static PVC tiles often require frequent maintenance to preserve their appearance and static-control performance, leading to additional labor costs and facility downtime. Our ESD vinyl tiles are designed for stable electrical performance, reliable durability, and easy daily cleaning, making them a practical flooring solution for electronics manufacturing, laboratories, cleanrooms, control rooms, and other static-sensitive environments.
| Property | Test Standard | Product Data |
|---|---|---|
| Use Classification | EN 685 / EN 649 | Class 34 + 43 |
| NFPA Life Safety Classification | NFPA 101 | Class I interior floor finish |
| Resilient Vinyl Floor Tile Specification | ASTM F1700 | Pass |
| European Product Requirements | EN 649 / SS-T-312B | Pass |
| Product Safety Performance | Underwriters Laboratories | Approved for static-conductive flooring used in hazardous locations |
| Total Thickness | EN 428 / ASTM F386 | 2.0 mm |
| Tile Size | EN 427 / ASTM F536 | 600 x 600 mm |
| Weight | EN 430 | At 2.0 mm: 3.06 kg/m² |
| Dimensional Stability |
SJ/T 11236-2001 EN 434 / DIN 51962 KS M-3802 (by heating) |
≤0.20% 0.10% <0.30% |
| Flexibility | ASTM F137 | No cracks |
| Squareness | ASTM F540 | 600 x 600 mm / ±0.30 mm |
| Residual Indentation |
SJ/T 11236-2001 EN 433 / DIN 51955 ASTM F142 |
≤0.30 mm 2.0 mm - 0.03 mm / 3.0 mm - 0.04 mm <8.0% |
| Abrasion Resistance / Wear Loss |
SJ/T 11236-2001 ASTM D1044 (CS-10-F wheel, 500 g) ASTM D4060 (CS-10-F wheel, 1000 g, 1000 cycles) |
≤0.020 g/cm² Weight loss: 2,500 cycles: 0.48 5,000 cycles: 0.95 7,500 cycles: 1.41 10,000 cycles: 1.87 |
| Hardness | ASTM D2240 | <85 |
| Resistance to Castor Chair | EN 425 | No damage |
| Static Load Limit | ASTM F970 | 1500 lb/sq.in |
| Electrical Resistance |
SJ/T 11236-2001 / YGJ 3007-97 DIN 51953 / EN 1081 IEC 61340 / EOS/ESD S7.1 ASTM F150 / NFPA 99 / UL779 |
EC conductive grade 10⁴ – 10⁶ Ω |
| Static Generation / Walking Voltage |
AATCC-134 SJ/T 10694-1996 |
<50 V <100 V |
| Static Decay |
101C, Method 4046; 5000V to 0 MIL-B-81705C (5KV Decay Time / sec) MIL-B-81705C (5KV decay time / sec) GJB2605-1996 |
<0.01 sec <0.02 sec 5000V ± 500V < 2 sec |
| Chemical Resistance | EN 423 / DIN 51958 / ASTM F925 | Excellent (detailed test results available) |
| Fire Resistance |
DIN 4102 / B3810 / B3800 SJ/T 11236-2001 GB 8624-1997 |
Non-burning, not easy to ignite FV-0, <10 s GB8624 B1 grade |
| Smoke Density | ASTM E662 / NFPA 258 | Class 1, <450 |
| Critical Radiant Flux | ASTM E648 / NFPA 253 / DIN 51960 | Class 1, >1.08 W/m² |
| Flame Spread | ASTM E84 / NFPA 225 | <75 |
| Outgassing | ASTM E595 | Excellent (detailed test results available) |
| Color Fastness | ISO 105 B02 / Method 3 / DIN 53389 | 5–6 |
| Decontamination Cleanability | DIN 25415-1 / ISO 8690 | Excellent |
| Water Absorption | ASTM D570 | <0.15% |
| Slip Resistance | EN 13893 / ASTM D2047 | 0.60 < μ < 0.80 / μ = 0.62 |
| Repairable | — | Yes |
| Recyclable | — | Yes |